Height above ground and why
The temperature sensor must be placed at a height of 2 meters – this is the official measuring height. It can be placed at a different height, but this is only in connection with special requests. The temperature in the weather forecasts is a 2 meter temperature. Another reason is that the temperature can vary with altitude, especially in winter when it is clear and windless. It can be around 4 degrees colder at ground level than at a height of 2 metres. If the temperature sensor is at a different height, this must be noted. It is possible on the basis of other parameters to determine the temperature, e.g. down at the ground surface.
The stations can be equipped with either one of the brands MetSpec, NGS or Vaisala, which is built together with the humidity sensor – see below.
Sheath/steel protection
Cover in which the sensor is mounted protects against solar radiation,
and which at the same time ensures good ventilation.
EE060 from E+E Elektronik
EE060 from E+E Elektronik
Specifications
Temperature
Operating range -40 to +60 °C
Accuracy ±0.3 gr. °C – at 20 gr.
Humidity
±2.5% at 20 °C
HMS83 from Vaisala
Specifications
Temperature
Operating range -40 to +60 °C
Accuracy ±0.3 gr. °C – at 20 gr.
Humidity
At temp. between +10 and +30°C
0-90% ±3%
90-100% ±5%
At temp. between -20 and +10°C
0-90% ±5%
90-100% ±7%
At temp. between -40 and -20 °C
0-100% ±7% Humidity ±2.5% RH at 20 gr.
HMP155 from Vaisala
The sensor may be supplied with a yellow protective cap – it must be dismantled.
Specifications
Operating range -39.2 to +60°C
Accuracy 0.2°C
The current version
The previous version
The sensor can be pulled off for replacement or adjustment
Soil temperature
The sensor for measuring the soil temperature must be buried 10 cm – under normal conditions.
Specifications
Operating range -55 to +125 °C
Accuracy 0.5 °C
The wire cannot be removed from the sensor
NGS sensor
Specifications
Operation range -40 to 52.5°C
Accuracy 1.1°C
Response time approx. 5 minutes
Wire connection Ready – signal – AI1
Black – minus – AGND
Red – plus – DCOUT
The cable cannot be dismantled on the sensor.